LFA-200 optical analyzer on a graphite plinth with a thin lime light beam entering its sample port
LABFORM InstrumentsAnalytical systems — Series 01

Precision youcan builddecisions on.

Advanced analytical instruments and measurement systems engineered to turn complex samples into dependable data.

LFA-200 · spectral range*190–1100nm*Illustrative demo value

01 — What we make

We build instruments for the moment a measurement becomes a decision: optical analyzers that run all day, metrology systems that measure without touching, and spectrometers small enough to go where the sample is.

We build instruments for the moment a measurement becomes a decision: optical analyzers that run all day, metrology systems that measure without touching, and spectrometers small enough to go where the sample is.

We build instruments for the moment a measurement becomes a decision: optical analyzers that run all day, metrology systems that measure without touching, and spectrometers small enough to go where the sample is.

Our engineering approach
All instruments
LFA-200 Optical Analyzer
02 — Series 01 instruments01 / 03
Optical analysis

LFA-200 — Optical Analyzer

Benchtop UV-Vis analysis with a 12-position drawer, for labs that measure all day.

Spectral range
190–1100nm
Repeatability
±0.05nm
Sample positions
12

03 — Operating principle

LFA-200

Follow the light through a measurement.

Follow the light through a measurement.

Follow the light through a measurement.

Four stages, one beam. Each stage is a sealed module that can be serviced without realigning the others.

Source
01

Source

A sealed lamp module emits a stable, broadband beam.

Separate
02

Separate

A ruled grating splits the light into single wavelengths.

Sample
03

Sample

Each wavelength passes through the sample in a 10 mm cell.

Detect
04

Detect

A photodiode array reads what the sample let through.

05 Result

An absorbance spectrum, stored with its raw data and audit trail.

LFA-200 details

05 — Engineering

Inside the LFA-200

Engineered to be opened.

Engineered to be opened.

Engineered to be opened.

Every module has one job and a defined interface. Nothing is glued, nothing is hidden, and every replacement part arrives with its own calibration data.

Analyzer with its side panel removed, showing the light source, optical bench, sample chamber, detector and control panel

01

Stable optics

The optical bench is thermally separated from the electronics, so the baseline holds between calibrations.

02

Traceable calibration

Each serial number ships with a calibration record and built-in verification routines.

03

Recorded data

Versioned methods, raw data kept with every result, and an exportable audit trail.

04

Modular service

Source, detector and sample handling are replaced as calibrated modules.

06 — Specifications

03 models

The series, side by side.

The series, side by side.

The series, side by side.

Key figures for engineers who already know what they need. Full tolerances and conditions are in each datasheet.

Compare all instruments

All values are illustrative demo content.

Key specifications (illustrative demo values)
SpecificationLFA-200Optical AnalyzerLFM-80Precision Measurement SystemLFS-40Laboratory Spectrometer
PrincipleUV-Vis absorbanceTelecentric imagingGrating · CMOS array
Range190–1100 nm80 × 80 × 50 mm350–1000 nm
Resolution1.0 nm0.1 µm1.5 nm FWHM
Repeatability±0.05 nm0.5 µm (2σ)±0.1 nm
Sample format10 mm cuvette · 12-pos.Parts ≤ 5 kgCuvette · SMA 905 fiber
W × D × H420 × 380 × 260 mm520 × 460 × 780 mm160 × 160 × 90 mm
Mass18 kg64 kg1.4 kg

07 — Technical documentation

Library

Everything procurement and QA will ask for.

Everything procurement and QA will ask for.

Everything procurement and QA will ask for.

Open the resource library
Gloved hand placing a cuvette into the sample drawer of an analyzer

Inquiry

Tell us what you need to measure.

Share your samples, throughput and documentation requirements. An applications specialist will recommend a configuration, or tell you if we are not the right fit.

Gloved hand placing a cuvette into the sample drawer of an analyzer

Inquiry

Tell us what you need to measure.

Share your samples, throughput and documentation requirements. An applications specialist will recommend a configuration, or tell you if we are not the right fit.

Gloved hand placing a cuvette into the sample drawer of an analyzer

Inquiry

Tell us what you need to measure.

Share your samples, throughput and documentation requirements. An applications specialist will recommend a configuration, or tell you if we are not the right fit.

Create a free website with Framer, the website builder loved by startups, designers and agencies.